Authors: |
Peter A. Dargaville,
Peter C. Rimensberger,
Inéz Frerichs
|
---|---|
Date: | 2010
|
Brief Description: |
The measurements were performed in two piglets (g08 and g10) during baseline conditions in healthy lung (g08-c003.get, g10-c003.get), after induction of acute lung injury by repeated bronchoalveolar lavage (g08-c017.get, g10-c019.get) and after administration of surfactant (g08-c035.get, g10-c029.get) during pressure-controlled ventilation. The EIT raw data were acquired during an incremental and decremental PEEP trial (stepwise increase and decrease of positive end-expiratory pressure from 0 cm H2O to 25 cm H2O and back) at a rate of 13 frames/s. Each measurement lasted 180 s. The excitation current was 70 kHz.
Data were published in Dargaville, P.A., Rimensberger, P.M., Frerichs, I. (2010) Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre. Intensive Care Med. 36:1953-1961. |
License: | Creative Commons Artistic License (with Attribution)
|
Attribution Requirement: |
Use or presentation of these data must acknowledge
Inéz Frerichs, and reference this publication:
|
Format: | Data are in *get files encoded in a zip file
|
Methods: | Pig torso. Single plane of
16 Electrodes numbered clockwise,
with electrode #1 at the anterior, electrode #5 at the right side, electrode #9 at the posterior and electrode #13 at the left side of the chest.
|
Data: | Data for animal g08 (zip format)
Data for animal g10 (zip format). The manoeuvre was performed in:
|